{"product_id":"smr25af25-25-gallon-side-mount-aluminum-hydraulic-reservoir-with-25-micron-filter","title":"SMR25AF25 - 25 Gallon Side Mount Aluminum Hydraulic Reservoir With 25 Micron Filter","description":"\u003cp\u003eThe 25 Gallon Side Mount Aluminum Reservoir with Micron Filter from Buyers Products features .125 thick aluminum construction to resist corrosion and provide good heat dissipation, and an integral welded-on aluminum bracket for mounting to the truck frame. Lightweight and high quality, it's ideal for running small applications such as landscaping or smaller city plows.   The reservoir has several features for optimal fluid operation, including: - a quarter-turn chrome filler breather with a wire basket strainer - a sight fluid level and temperature gauge - an interior baffle between suction and discharge to aid in fluid cooling - a magnetic drain plug to aid in preventing metallic particle contamination  The reservoir comes pre-drilled for an included tank-mounted HFA5S series return filter. Choose from a 10 or 25 micron filter (shipped separately). It comes fully tested.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable style=\"border-collapse:collapse; width:100%; font-size:14px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eAdditional Port Size\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e1 1\/4 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eCapacity\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eColor\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eDepth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e15.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eDiffuser Included (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eFilter Head Material_1\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eFinish\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eSmooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eHardware and Brackets Included (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e20.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eIncluded Valve (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eIntegral Brackets (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eIntegral Level Gauge (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border-1px solid #e5e7eb; background:#f9fafb;\"\u003eMagnetic Drain Plug (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eMaterial Gauge\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eMount Position\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eSide Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eMount Style\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eSide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eOil Level Gauge (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eReservoir Shape\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eRectangle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eReturn Line Filter Included (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eReturn Line Filter Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eStyle 1 Port Diameter\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eStyle 2 Port Diameter\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e1-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eSuction Port Size\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e2 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eTemperature Gauge (y\/n)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eUsable Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left; padding:6px 10px; border:1px solid #e5e7eb; background:#f9fafb;\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px; border:1px solid #e5e7eb;\"\u003e24.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAdvanced Engineering: The 25 Gallon Side Mount Aluminum Hydraulic Reservoir with 25 Micron Filter\u003c\/h2\u003e\n\u003cp\u003eThe 25 Gallon Side Mount Aluminum Hydraulic Reservoir with an integrated 25 Micron Filter represents a pinnacle in mobile hydraulic fluid management, meticulously engineered to deliver superior performance, longevity, and reliability for demanding applications. Designed by Buyers Products, this unit is not merely a fluid storage container but a comprehensive subsystem critical to the health and efficiency of your hydraulic operations. Its robust construction, thoughtful feature set, and integrated filtration system underscore its role as an indispensable component in a wide array of mobile and stationary hydraulic power units.\u003c\/p\u003e\n\n\u003ch3\u003eMaterial Science and Structural Integrity: The Aluminum Advantage\u003c\/h3\u003e\n\u003cp\u003eAt the core of this hydraulic reservoir's exceptional performance is its construction from premium aluminum, boasting a nominal .125 inch (1\/8 inch) thickness. This material choice is a deliberate engineering decision, offering a trifecta of benefits critical for hydraulic systems:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSuperior Corrosion Resistance:\u003c\/strong\u003e Aluminum inherently forms a passive oxide layer, providing an exceptional barrier against corrosion, particularly in harsh environmental conditions prevalent in mobile applications. Unlike steel reservoirs which often require extensive coating systems to prevent rust, aluminum offers intrinsic protection, significantly extending the service life of the reservoir, especially when exposed to road salts, moisture, and various industrial chemicals. This resilience ensures structural integrity and preserves the aesthetic finish over time, reducing maintenance requirements and associated costs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExceptional Heat Dissipation:\u003c\/strong\u003e Aluminum possesses a significantly higher thermal conductivity compared to steel. This property is crucial for hydraulic systems, as efficient heat dissipation from the hydraulic fluid is paramount to prevent thermal degradation of the oil. Overheated hydraulic fluid can lead to accelerated wear of components, reduced viscosity, seal hardening, and premature component failure. The large surface area of the aluminum reservoir, coupled with its excellent thermal transfer capabilities, facilitates passive cooling, helping to maintain optimal fluid operating temperatures and thereby enhancing system efficiency and component longevity.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOptimized Weight-to-Strength Ratio:\u003c\/strong\u003e The lightweight nature of aluminum is a considerable advantage, particularly for side-mount applications on vehicles. Reducing the overall vehicle weight translates directly into increased payload capacity, improved fuel efficiency, and reduced wear and tear on vehicle suspension components. Despite its light mass, the .125 inch thick aluminum construction, reinforced by expertly welded seams, provides ample structural strength to withstand the dynamic stresses and vibrations inherent in mobile hydraulic operations, ensuring dependable performance in rugged conditions. The integral welded-on aluminum brackets provide a secure and robust mounting solution directly to the truck frame, emphasizing structural integrity and ease of installation, eliminating the need for separate, potentially weaker, mounting hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eStrategic Fluid Management: Beyond Simple Storage\u003c\/h3\u003e\n\u003cp\u003eThe 25-gallon capacity of this reservoir is strategically sized to accommodate a range of small to medium hydraulic applications, including landscaping equipment, smaller city plows, utility vehicles, and auxiliary power units. Proper reservoir sizing is fundamental in hydraulic system design, ensuring adequate fluid volume for:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e A larger fluid volume provides a greater thermal mass and surface area for heat exchange, directly supporting the aluminum's thermal properties.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eContaminant Settling:\u003c\/strong\u003e Increased fluid residence time allows suspended particulate contaminants to settle to the bottom, where they can be effectively managed by the magnetic drain plug and filtration system.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAir Release:\u003c\/strong\u003e Sufficient volume and a well-designed internal structure facilitate the release of entrained air, preventing cavitation and associated damage to hydraulic pumps and other components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eA critical internal feature enhancing fluid management is the \u003cstrong\u003eintegral baffle\u003c\/strong\u003e strategically placed between the suction and return lines. This baffle serves multiple essential functions:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended Fluid Path:\u003c\/strong\u003e It forces the return fluid to travel a longer path through the reservoir before being drawn back into the suction line. This extended residence time is vital for several processes.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnhanced De-aeration:\u003c\/strong\u003e It allows more time for entrained air bubbles to rise to the surface and escape, mitigating the risks of cavitation, pump noise, and reduced volumetric efficiency.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eImproved Heat Exchange:\u003c\/strong\u003e The extended path maximizes exposure of the fluid to the reservoir walls, enhancing passive cooling and contributing to thermal stability.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAccelerated Contaminant Settling:\u003c\/strong\u003e It reduces fluid velocity, promoting the gravitational settling of heavier particulate contaminants to the reservoir bottom, away from the pump's suction port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePrecision Contamination Control: The Integrated 25 Micron Filtration System\u003c\/h3\u003e\n\u003cp\u003eContamination is the leading cause of hydraulic system failure, with an estimated 80% of component wear attributable to particulate and fluid contamination. This hydraulic reservoir tackles this challenge head-on with an advanced, integrated filtration strategy:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTank-Mounted HFA5S Series Return Filter:\u003c\/strong\u003e The reservoir comes pre-drilled for an included HFA5S series return filter, emphasizing its commitment to proactive contamination control. Return line filters are strategically placed to capture contaminants generated within the system (e.g., from component wear) before the fluid returns to the main reservoir for recirculation. This prevents re-contamination of the entire fluid volume.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e25 Micron Filtration Rating:\u003c\/strong\u003e The included 25-micron filter (with an option for a finer 10-micron filter) is highly effective at removing solid particulate matter that can damage critical hydraulic components. To put this into perspective, a human hair is typically 50-70 microns thick. A 25-micron filter captures particles significantly smaller than what is visible to the naked eye, targeting the size range most damaging to pumps, valves, and cylinders. This level of filtration significantly extends the life of hydraulic fluid and components, reducing maintenance intervals and operational downtime. The filter head itself, also constructed from aluminum, maintains material consistency and corrosion resistance throughout the filtration assembly.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMagnetic Drain Plug:\u003c\/strong\u003e Complementing the particulate filtration, the reservoir features a magnetic drain plug. This plug is designed to attract and hold ferrous metallic particles (such as wear debris from pumps, motors, or valves) that are too small or light to settle effectively or that might bypass other filtration stages. Its presence is a critical first line of defense against internal ferrous contamination, providing an excellent diagnostic tool for early detection of component wear and aiding in overall system cleanliness. Regular inspection and cleaning of the magnetic drain plug can offer valuable insights into the health of the hydraulic system and prevent more severe damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe combination of return line filtration and magnetic particle removal creates a multi-layered defense against both general particulate and metallic wear contamination, ensuring a cleaner operating environment for the hydraulic fluid and components.\u003c\/p\u003e\n\n\u003ch3\u003eOperational Monitoring and User-Centric Features\u003c\/h3\u003e\n\u003cp\u003eOperational efficiency and system health are further supported by a suite of user-friendly monitoring and access features:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eQuarter-Turn Chrome Filler Breather with Wire Basket Strainer:\u003c\/strong\u003e This component serves a dual vital role. As a breather, it allows the reservoir to \"breathe,\" equalizing pressure changes due to fluid level fluctuations and temperature variations, preventing vacuum formation or over-pressurization. The integrated air filter element within the breather prevents airborne contaminants (dust, dirt, moisture) from entering the system. The wire basket strainer provides a coarse initial filtration during fluid addition, preventing larger debris from entering the reservoir during filling. Its quarter-turn design ensures quick and secure access for fluid top-ups, while the chrome finish adds durability and resistance to environmental elements.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSight Fluid Level and Temperature Gauge:\u003c\/strong\u003e Real-time monitoring of fluid level and temperature is paramount for hydraulic system health. The integrated sight gauge allows operators to quickly ascertain the fluid level, preventing costly pump damage due to cavitation from insufficient fluid. Simultaneously, the temperature gauge provides an immediate indicator of fluid thermal conditions, allowing proactive intervention if temperatures approach critical limits, thereby preventing fluid degradation and component damage. This continuous visual feedback empowers operators and maintenance personnel to ensure the system operates within safe parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSeamless Integration and Technical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe reservoir's design facilitates straightforward integration into existing mobile hydraulic setups. The side-mount configuration, coupled with integral welded brackets, ensures a secure and stable attachment to the vehicle frame, optimizing space utilization and minimizing installation complexity. The unit's precise dimensions—approximately 24.00 inches in width, 15.04 inches in depth, and 20.15 inches in height—are engineered for compactness without compromising critical fluid volume or cooling capabilities.\u003c\/p\u003e\n\u003cp\u003ePort sizing is a crucial element for efficient hydraulic flow. The reservoir features a 2 NPT suction port and an additional 1 1\/4 NPT port (Style 2 Port Diameter is 1-1\/4, Style 1 Port Diameter is 2). These NPT (National Pipe Taper) threaded ports provide industry-standard connections for hydraulic lines, ensuring compatibility and secure, leak-free connections. Adequate port sizing minimizes pressure drop and turbulence, contributing to overall system efficiency and reducing the risk of cavitation at the pump inlet.\u003c\/p\u003e\n\u003cp\u003eThe smooth, black finish not only provides a professional aesthetic but also adds an additional layer of protection against environmental elements, contributing to the reservoir's long-term durability and appearance.\u003c\/p\u003e\n\n\u003ch3\u003eVersatility Across Applications\u003c\/h3\u003e\n\u003cp\u003eWhile ideally suited for landscaping and smaller city plows, the robust design and advanced features of this 25 Gallon Side Mount Aluminum Hydraulic Reservoir extend its utility to a broader range of applications:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMunicipal Fleets:\u003c\/strong\u003e Beyond plows, for salt spreaders, brine sprayers, and other auxiliary functions on municipal vehicles.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUtility Services:\u003c\/strong\u003e Powering hydraulic tools and equipment on utility trucks, such as aerial lifts, winches, and pole setters.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLight Construction:\u003c\/strong\u003e Enabling hydraulic functions on compact excavators, skid steers, and other light-duty construction machinery.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAgricultural Equipment:\u003c\/strong\u003e Providing hydraulic power for various implements on smaller tractors and specialized farm equipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSpecialized Mobile Equipment:\u003c\/strong\u003e Custom builds requiring a reliable, compact, and efficient hydraulic fluid storage and conditioning unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInvestment in Longevity and Reliability\u003c\/h3\u003e\n\u003cp\u003eChoosing the 25 Gallon Side Mount Aluminum Hydraulic Reservoir with 25 Micron Filter is an investment in the long-term health and efficiency of your hydraulic systems. Every design element, from the .125 inch thick aluminum construction to the integrated filtration and monitoring components, is aimed at reducing wear, preventing contamination, managing thermal loads, and ultimately extending the service life of expensive hydraulic pumps, valves, and actuators. The \"fully tested\" assurance provides peace of mind, confirming that each unit meets stringent quality and performance standards before deployment. By mitigating the most common causes of hydraulic system failure, this reservoir ensures reduced downtime, lower maintenance costs, and consistent, reliable performance in the most demanding operating environments.\u003c\/p\u003e","brand":"buyersproductscompany","offers":[{"title":"Default Title","offer_id":62449260953971,"sku":"SMR25AF25","price":660.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/9513\/9187\/files\/SMR25AF10_SMR25AF25_drawing_0b996a46-ea8b-4e4f-958c-48a693029548.jpg?v=1768842152","url":"https:\/\/titustrucksaccessories.com\/products\/smr25af25-25-gallon-side-mount-aluminum-hydraulic-reservoir-with-25-micron-filter","provider":"Titus Trucks Accessories ","version":"1.0","type":"link"}